Application Guide

Sulphuric Acid Transfer Pumps

From dilute to 98% — the material answer changes completely.

Sulphuric acid spans the widest material range of any common industrial liquid: dilute grades are handled economically in PP, while concentrated 98% acid demands PVDF or specific alloys. Dilution is intensely exothermic — temperature at the pump is often higher than the tank reading suggests.

The pumping challenges

  • Concentration completely changes material compatibility
  • Dilution heat spikes liquid temperature at the pump
  • 98% acid has SG ~1.84 — nearly double water's power demand
  • Air ingress on suction side accelerates corrosion

Material options

PP for dilute grades below 70 °C
PVDF for concentrated acid and higher temperatures
Alloy 20 construction available for specific metallic requirements

Technical considerations

  • SG 1.84 at 98% roughly doubles shaft power — motors must be sized on SG, not water
  • Seal-less magnetic drive strongly preferred for concentrated acid
  • Confirm whether duty is transfer, circulation or tanker unloading — suction conditions differ
  • Temperature measured at the pump, not the storage tank

Honest limits: no pump material is universally compatible with every concentration and temperature of a chemical. Final selection is confirmed against your exact duty — that's why we ask before we quote.

Suitable PT Pumps

Pumps for this duty

FAQs

Common questions on this duty

No. Dilute acid (below ~50%) runs comfortably in PP; concentrated 98% acid needs PVDF or specific alloy construction, and its high specific gravity demands a larger motor. We select against your exact concentration and temperature.
Enquire

Get a pump selected for this duty

Fill in the duty point — the form is pre-tagged for this application. An applications engineer responds with a confirmed selection and budgetary quotation.

Duty point — helps us quote faster

Technical response within 24 working hours. Your details are used only to answer this enquiry.